Riello Sentinel Dual 10KVA Online (UPS) – SDU 10000 TM
£833.33 EX VAT
The Sentinel Dual 10000 TM is an excellent choice for any IT equipment or critical infrastructure built with superior power protection. Your mind can rest easy, knowing you won’t lose any data or machine downtime. The Sentinel Dual 10000 TM is built to have a three-phase input and a single phase output allowing flexibility with your power distribution.
The Sentinel Dual range is built with the double conversion online to ensure protection from; power outages, power sags, overvoltages, power surges, brownouts, electrical lines, frequency variation, switching transients and harmonic distortion.
The Sentinel Dual 10000 TM is rated for 10000 Watts to power your storage servers, networking equipment, monitoring devices and more. The Sentinel Dual range also can be mounted in a tower or rack format with ease, and a rotating display means you can easily monitor your UPS in either orientation.
-
Features & Benefits
Highly versatile, quality power, excellent efficiency – just three reasons why the Sentinel Dual is one of Riello UPS’s best-selling products.
Available in 4-5-6-8-10 kVA power ratings, the SDU is designed to handle non-linear loads like blade servers and electro-medical devices, making it a great choice for protecting Edge applications too.
Parallel up to 3 Sentinel Duals together for greater power, autonomy, or redundancy. While extended runtime versions (6 kVA and 10 kVA models only) are available for applications needing several hours’ autonomy. Automatic and manual battery testing help enhance reliability and maximise lifespan.
Installation Versatility
Doubly versatile SDU operates as either a 3U rackmount UPS (6U for 8-10 kVA versions) or as a floor-standing tower. Just use the rack supports or additional handles depending on your installation environment.
Easily rotate the backlit LCD display and control panel 90 degrees to suit your preferred configuration.
Simple Scalability
Parallel up to 3 Sentinel Duals together to increase power, redundancy, or battery runtime. Can run multiple UPS in either capacity or N+1 parallel redundant configuration.
Prioritise Devices With Load Shedding
A configurable EnergyShare IEC connection socket enables you to shut down non-critical loads in the event of a mains failure, prioritising runtime to your most important equipment.Quality Power
The SDU delivers unity power (except 4 kVA version) and 95% operating efficiency in ONLINE double conversion mode, meaning you get more real output power.
With a high overload (up to 150%) and short circuit capacity, it’s also designed to deal with non-linear loads with a crest factor up to 3:1.
Fantastic Functionality
Choose from a range of operating modes including ECO (efficiency of 98%) and Smart Active. Generates minimal (< 45 dBA) noise as fan speed automatically adjusts.
Automatic and manual battery testing, with hot-swappable, user-replaceable batteries that ensures downtime-free maintenance.
-
Technical Data
Input Dual Input no Rated power 10000 VA Voltage 380-400-415 Vac (3W+N+PE) 220-230-240 Vac (1W+N+PE) Voltage tolerance 242 Vac < Vin < 478 Vac @50% LOAD / 318 Vac < Vin < 478 Vac @ 100% LOAD (3W+N+PE) Load (1w+n+pe) Frequency 50/60 Hz 5 Hz Frequency tolerance 50 Hz 20% / 60 Hz 20% Power factor >0.98 Current distorsion 5% By Pass Voltage tolerance 180264 Vac (selectable in Economy Mode and SMART ACTIVE Mode) Frequency tolerance Selected frequency 5% (user configurable) Number phases 1 Output And Inverter Output Rated power 10000 VA Active power 10000 W Crest factor (Ipeak/Irms) 3 : 1 Waveform Sinewave Frequency 50/60 Hz selectable Voltage distortion with distorcing load <3% Voltage distortion with linear load <1% Inverter efficiency at rated load 95% Overload Times 100% < Load < 110% activates the bypass after 10 min Continues to work on by-pass 110% < Load < 133% activates the bypass after 1 min shut down after 1 hour 133% < Load < 150% activates the bypass after 5 s shut down after 10 min Load > 150% activates the bypass instantaneously shutdown after 3 s (load > 150%) shutdown after 2 s (load > 200%) Batteries Type VRLA AGM lead, maintenance-free Typical recharge time 46 h -
Additional information
Phase Single Phase
Power 0-10 KVA
- Downloads
Whatever your industry we offer a range of market leading UPS services from installation and maintenance, to rentals and relocation.
UPS Services
When critical systems go down, you need a UPS support team who understands that a fast response is vital. Our support team covers the widest range of maintenance tasks all across the UK and every job we undertake is handled strategically to guarantee the most beneficial solution for you. From product supply to technical support, our UPS services bring together some of the most talented technical brains in the industry to ensure you get the very best UPS solution for your business. Whether you’re considering a new design and installation, or looking at a power protection upgrade, our trusted experts are on hand to provide decades of UPS experience underpinned by a commitment to excellence.
Generator Services
We offer a turnkey solution for power protection systems, offering clients market-leading generators with outstanding power and cutting-edge modular design. We are dedicated to helping clients find the most appropriate generator system and service package that will exceed expectations. The specialist team at Advanced Solutions has vast experience in supplying backup generators which, when coupled with our expert in-house technical support, offers peace of mind about the life-long and reliable operation of your services.